The following instructions on how to wind magnetic pulse
coils is extracted from Bob Beck's paper on the HIV Neutralizer. This coil
is similar to those used with the Radio Shack strobe light known as the
'Mr. Thumpy' modification.
If you want to buy an off the shelf coil that works just fine, check
out the end of this page. Revision December 18, 1995. Note: These data are for informational and instructional purposes only and are not to be construed as medical advice. Consult with your licensed health practitioner. In keeping with do-it-yourself inexpensive hypothetical approaches to self- help, the simplest and most rapid means for obtaining a capacitor-discharge magnetic pulse lymph and tissue pathogen neutralizer would be to find and modify a used functioning portable battery AND AC powered electronic flash (strobe light) for cameras. These are acquired at swap meets, yard sales, pawn shops, or in junk boxes at used camera stores. Or purchase a new Vivitar (brand) model 1900 ($22) carried at some professional camera stores. This compact, light weight, inexpensive, rapid recharging flash is only 17.5 Watt-seconds power but is readily available and easily modified. It works well enough for casual use but runs on batteries only so has greater operating expense than an AC/DC unit. California swap meet prices for USED strobes range from $4.00 to about $18.00. One Sunday the writer found a dozen ac/dc strobes, all in good working condition. Carry four AA batteries with you so you can test flash units before purchasing. I chose to modify a long-discontinued Vivitar (brand) model 110 because
it was larger than the rest and seemingly more powerful, however almost
any brand or model of comparable output power (35 watt-seconds) should
work. PREFERABLY SELECT ONE WITH 115V AC AS WELL AS BATTERY OPERATING
(DC) CAPABILITY. Drill 1/4" holes through hub and through center of flange(s). Make two 4" discs from 1/4" thick plastic or fiberboard, drill 1/4" center holes and another 1/4" hole off-center so coil's inside lead wire can be pulled through. These stiffeners will sandwich reel's flanges so they won't warp or
split as wire pressure builds up while winding progresses. A 2" (or
longer) 1/4-20 machine nut and bolt with washers through centers will
clamp flange stiffeners and reel and also provide a shaft to hold in
a variable speed drill motor or similar winding device if used. Then
remove bolt and stiffeners. Pull inside end of magnet wire through hub and stiffener and to outside. ~130 turns (about three 1/2 Lb rolls spliced together) should fill spool. Remove bolt, stiffeners, and finished coil. Now solder ends of 3 ft of HEAVY two-wire extension cord to each side of coil. Finished coil weighs ~1 LB 3 oz, has ~0.935 millihenry inductance, 0.34 W resistance, and takes ~20 minutes to hand wind or ~3 min. with drill motor. David Cowlishaw used fingernail polish to secure the wires in his coil, this prevents motion of the wire when the magnetic pulse fires. You could also use RTV/silicone or other caulking compounds not only as insulators but for motion suppression. An excellent alternative is an AMS brand air-core crossover inductor
for home audio, MCM Electronics, Centerville, OH 45459, (800) 543-4330
catalog # 50- 940, #16 gauge, 0.58W, 2.5mH, 2-7/8" dia., $10.65. Before modifying and to avoid shock, short out the capacitor by placing clip leads directly across the flash tube. Remember to remove this shunt later. To install coil, unsolder either wire from flash tube and connect one lead wire from coil to that side of tube. Connect the other lead from coil to the wire you just removed from tube. Insulate connections with tape. This places your coil IN SERIES with the flash tube and enables the tube to act as an ionized gas relay or "thyratron" that dumps most of capacitor's stored energy through coil when fired. Lamp will still flash but less brightly. Cover flash window with black
paper. Replace case. You're done! Let the flash unit charge for about ten seconds plus or until the strobe's ready light comes on then push flash button and see how high the washer is kicked by Eddy current repulsion. A 35 watt-second strobe repels a washer about 14 inches vertically. Think of your pulsed coil as the primary of a transformer and anything conductive nearby (living tissue included) as the secondary into which current is induced when cut by coil's time-varying magnetic lines of flux. Your do-it-yourself magnetic pulse generator delivers a measurable output intensity SEVERAL THOUSAND TIMES more powerful during each cycle than $7,000.00 German Magnetotrons, Elecsystem Biotrons, or Canada's Centurion devices widely exhibited at holistic medical expos, none of which is NEARLY powerful enough for HIV, herpes, hepatitis or Epstein-Barr neutralization or adequate electroporation. It is also functionally similar to the Diapulse miracle-working healing modality when coil is applied over liver and other organs. Magnetic fields and therefore induced currents penetrate ALL body cells, bones and tissues in proximity to coil (effective approx. 4 inches deep) and can theoretically neutralize electro-sensitive viruses such as herpes B, HIV, hepatitis, Epstein-Barr and possibly many others as yet undiscovered that can hide WITHIN nerve sheaths and are therefore untouchable via immune system, white cells, or injectables. This may account for the impossibility of curing many known chronic infections via pharmaceuticals, antibiotics, or any presently known conventional treatments other than electrotherapy. Use pulser on body sites daily concurrently with blood clearing. This
pulser is considered safe to use anywhere on the head, chest, and body
except with cardiac pacemaker users. Subjects will feel no physical sensations except for light thumps during this phase of treatment. Exposure levels are considered safe because intensity of this magnetic pulser is much lower than Magnetic Nuclear Resonance Imaging in routine use on tens of thousands of patients. But should subject feel headachy, nauseous, sluggish, or display flu-like symptoms after exposures with either of these two devices, reduce number of pulses or duration of blood clearing process and drink more water. If immune system is very badly damaged, you may need to repeat all routines after several months to insure permanent and complete neutralization. WHEN USING, KEEP COIL SEVERAL FEET AWAY FROM CREDIT CARDS, WATCHES, MAGENTIC TAPE, COMPUTERS, FLOPPY DISKS, HOMEOPATHIC REMEDIES, ETC., since its powerful magnetic field can de-gauss and erase magnetic data as well as subtle energy potentized medicines. As an unanticipated serendipity, pulsers are reported to erase deeply rooted lymph and tissue pathology and possibly even classical miasma's as well as many other microbes, fungi, bacteria, parasites, and viruses. Flash should preferably be used with AC power to save battery costs
since you'll only get about 40 full pulses per new set of alkaline batteries.
For sanitary purposes, enclose coil in plastic zip-lock sandwich bag
discarded after each user. When treating numerous subjects if there's
no AC adapter it is economical to purchase and utilize a small rechargeable
6V lead-acid motorcycle type storage battery. A company called Parts Express (800) 338-0531 or http://www.parts-express.com sells two different types of coils. A wound 14 gauge air coil rated at 2.5 mH at .36 ohms that is 3 and 11/16" in diameter is available under part number 266-380. According to Beck, the hand wound coil you would wind up with should be rated at ~0.935 mH (millihenry inductance), 0.34 Watt resistance. Another interesting coil Gene mentions is rated 14 gauge, goes up to 4.7 mH at .52 ohms and has a diameter of 4.24". The part number for this coil is 266- 738 http://keelynet.com/biology/thumcoil.htm |