AUTOGENIC AT53Dual Channel EMG |
AT 53 DUAL CHANNEL EMG SPECIFICATIONS
The AT 53 is designed to meet or exceed the electrical and safety standards
specified by UL 2601, IEC 601 and CSA 871. The default parameters are bolded
.
Channels
Two Channels A only, B only, A/B, A+B Simultaneously
Home-Use Software Lockout Enabled, Disabled
Visual Feedback -- Per Channel
Display Options Per Channel Numerical LED + Lightbar , Lightbar only,
Numerical LED only, A/B Ratio
TPI (Time Period Integration) Settings 0.5 , 1.0, 2.0, 4.0, 6.0,
10.0, 60.0 seconds
LVA (Last Value Attained) Settings Continuous , Maximum, Minimum
Audio Feedback -- Per Channel
Tones Piano , Continuous, Clicks, Raw
Volume Levels 0 to 7, 4 is the default
Audio Provided Continuously, Above or Below Threshold, After 3 or
5 seconds
Statistics -- Per Channel
Statistics Acquired (Summary) Min., Max., Mean, STD, %STD, %Time>Threshold,
%Time<Threshold Statistics Acquired (Intra-Stats) Choice of Min., Max.,
Mean , STD, %STD, %Time>Threshold, %Time<Threshold
Sampling Capacity 30 to 300 minutes of data (depending on the sampling rate)
Intra-Session Data Collection Rate 0.5, 1.0 , 2.5 or 5.0 minutes,
Data Display Rate 2.5 seconds Statistics Sampling Rate 4 Hz (every
0.25 seconds) or V RMS
Electrical -- Per Channel
Numerical LED Displays Red, 7 segment, 2 decimal Low-power
Numerical LED Range 0.01 - 999 microvolts, auto-ranging
Lightbar Range 15 segments, logarithmic scale corresponding to threshold
setting
Resolution 0.10 microvolts
Bandpass 25-425 Hz
Bandpass Rolloff 18 dB per octave
Common Mode Rejection 120 dB
Notch Filter 60 Hz, 25 dB, (50 Hz option)
Differential Input Impedance >1,000,000 megohms
Input Noise 0.3 microvolts
Leakage Current In compliance with UL 2601 specifications
Audio Output 3.5 mm stereo earphone jack, (mono output)
Analog Output Linear 0-5 volt DC signal
Line Power Input 120 volt, 60 HZ , 220 volt, 50/60 Hz
Battery Rating 10 to 12 hours continuous use
Battery Recharge 16 hour recharge maximum
Battery Overcharge Protection Yes
External Stimulator Signal Duration 0.6, 0.8, 1.0 , 1.2, 1.4, 1.6,
1.8, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0, 8.0, 9.0, 10.0 seconds
External Stimulator Triggered Above, Below EMG threshold level
Mechanical
Dimensions 2.5"H x 7.7"W x 5.3"D
Weight 1 pound 11 ounces
Warranty 1 year parts and labor, 3 year extended warranty available
STANDARD ACCESSORIES
(1) UL listed isolation adapter
(4) Installed Ni-Cad rechargeable batteries
(2) 6-foot sensor cables
(1) Leather strap for ambulatory use
(50) Quick-Stick pre-gelled EMG electrode sets
(1) Carrying case
(1) Top cover instruction label
(1) Owners manual
Indications: EMG biofeedback is indicated where general relaxation
training or muscle reeducation is desired. Contraindications: There
are no known contraindications with the AT 53 EMG for the purpose of general
relaxation training or muscle reeducation.
NOTE: No warranty or claim is made regarding the efficacy of products
in clinical use, but only with regard to electronic specifications, which
specifications are subject to change without notice.
NOTE: Federal Law (USA) restricts this device to sale by or on the
order of a physician or other health practitioner licensed by the state.